Elicit: Impact of Continuous Glucose Monitors on Diabetes Complications

Impact of Continuous Glucose Monitors on Diabetes Complications

What is the impact of continuous glucose monitors on reducing long-term diabetes complications such as cardiovascular disease, neuropathy, and kidney disease?

Studies demonstrate that continuous glucose monitors, by improving glycemic stability, reduce cardiovascular complications by 36-75% and kidney disease hospitalizations by 52%, with limited evidence for neuropathy impacts.

Abstract

Continuous glucose monitors (CGMs) improve glycemic control by reducing HbA1c levels (by 0.2%–0.76%), increasing time in range, and lowering hypoglycemia exposure. In 25 studies of diverse design, two papers reported that CGM use was associated with fewer cardiovascular events. One reported relative risk reductions of 52% for stroke (RR 0.48), 36% for myocardial infarction (RR 0.64), 41% for atrial fibrillation (RR 0.59), and 75% for heart failure (RR 0.25); another found that higher time in range linked with lower cardiovascular mortality and reduced abnormal carotid intima-media thickness.

Similarly, two studies addressed renal outcomes. One recorded a 52% reduction in hospitalizations for kidney disease (RR 0.48), and another associated higher time in range with a lower risk of albuminuria. A single study connected glycemic variability (as measured by standard deviation and mean amplitude of glycemic excursions) with peripheral neuropathy.

Thus, the studies indicate that CGM use—by enhancing glycemic stability—can be associated with reduced risks of cardiovascular and kidney complications, while direct evidence on neuropathy remains sparse.

Methods

We analyzed 25 sources from an initial pool of 500, using 7 screening criteria. Each paper was reviewed for 5 key aspects that mattered most to the research question.

Screening

We screened in sources based on their abstracts that met these criteria:

Results

Effects of Continuous Glucose Monitoring (CGM) on Diabetes Complications

Cardiovascular Outcomes

Study Outcome Type Effect Size Follow-up Duration Key Findings
Eeg-Olofsson et al., 2024 Hospitalization for cardiovascular events Relative risk reductions No mention found Stroke: Relative Risk (RR) 0.48
Yapanis et al., 2022 Cardiovascular disease mortality No mention found Higher time in range associated with reduced risk

Neurological Complications

Study Outcome Type Effect Size Follow-up Duration Key Findings
Yapanis et al., 2022 Peripheral neuropathy No mention found Associated with glycemic variability measures

Renal Outcomes

Study Outcome Type Effect Size Follow-up Duration Key Findings
Eeg-Olofsson et al., 2024 Hospitalization for kidney disease Relative risk reduction No mention found Relative Risk (RR) 0.48
Yapanis et al., 2022 Albuminuria No mention found Higher time in range associated with reduced risk

Implementation Factors

Duration of Continuous Glucose Monitoring (CGM) Use

The duration of CGM use varied widely across studies:

Technology Type Impact